Conductive foam

“Anti-static foam” and “conductive foam” are often used as if they were grades of the same thing, one stronger than the other. They are not. They answer two different questions, and choosing the wrong one is a design error that a passing resistance test will not catch. This article sets out the difference, what actually has to be measured, and the claims that no foam data sheet can support.

Two ranges, two jobs

At Bofeng Foam the two IXPE grades are:

  • Anti-static (dissipative): surface or volume resistance in the range 10⁶–10⁹ Ω.
  • Conductive: resistance in the range 10³–10⁶ Ω.

The anti-static grade is used where the aim is to stop charge building up on a surface that is handled near sensitive parts, without providing a low-resistance connection to anything. The conductive grade is used where charge must be carried to a ground, or where two conductive surfaces need a contact path — a grounding pad, a contact cushion, a divider that is part of the grounding route.

Neither grade is “better”. A conductive part placed where the ESD plan wanted a dissipative surface can create a fast discharge path that the plan did not intend. A dissipative part placed where a grounding path was required leaves the path open. The grade follows the ESD control plan, not the product name.

The question the number does not answer: surface or volume

A resistance reading has a quantity attached to it. Surface resistance describes the current that flows across the surface between two electrodes. Volume resistance describes the current that flows through the thickness of the material. The two can differ by orders of magnitude on the same sample.

If a specification says “10⁶–10⁹ Ω” without saying which quantity, it is incomplete. The purchase drawing should state the quantity, the standard, the electrode geometry, the specimen size, the applied voltage, the electrification time, the conditioning (temperature and relative humidity, with equilibration time) and the reading time. A reading produced under different conditions is not comparable, even when the number looks the same.

Contact resistance is a different measurement

Many conductive foam parts are also contact parts. In that role, the interface matters as much as the material. Contact area, compression, surface finish, oxidation, contamination and the mating material all change the result. A material with a low resistance can still give a high contact resistance in an assembly, and the only way to know is to test the actual contact face at the installed compression.

This is why a purchase specification for a grounding pad should include the mating surface, the installed compression and the cleaning exposure — not just the material range.

Compression changes the answer

A foam cushion that carries current is compressed. IXPE compression set runs from ≤2% at 3× expansion to ≤11% at 40× under the published 23±2 °C, 22 h test. The installed compression, the load it develops and the relaxation over service life all belong in the specification. A pad specified only by density and resistance leaves the assembly behaviour undefined.

What a resistance range does not mean

Four claims come up in every conversation about these grades, and none of them follows from a resistance number:

  • It is not a shielding rating. Shielding effectiveness is measured in dB by frequency. A conductive foam is not an EMI/RFI shield, and we do not publish a shielding figure.
  • It is not a dielectric rating. We do not publish breakdown voltage, dielectric strength or a tracking index. The foam must not be used as the insulation between a live conductor and a person.
  • It is not a cleanliness claim. We do not publish particle counts, ionic contamination, outgassing or a cleanroom class. If a line needs them, they must be agreed for the grade and validated on the part.
  • It is not a lifetime promise. Resistance and contact resistance change with humidity, temperature, cleaning, abrasion and handling. The retest interval belongs to the customer’s qualification.

Flame ratings are a separate matter again. A flame-retardant grade can be supplied with LOI 27, GB 8410 A0 and UL94 V2. Those are material-level ratings; UL94 V0 is not offered and should not be assumed.

Why IXPE for thin parts

IXPE is irradiation cross-linked polyethylene foam. The electron-beam route gives a fine closed-cell structure, a smooth surface and a single-layer thickness from 0.1 mm. For a thin grounding pad, a slot liner or a die-cut contact cushion, that thin end matters: the part can sit in a gap without adding height. The base range is 3–40× expansion, 26.8–300 kg/m³, widths 500–2000 mm, with heat-bonded sections from 15 to 200 mm.

Not every IXPE sheet is conductive or anti-static. The functional grade is a selected compound and must be named on the order and on the test report. Do not infer the grade from colour.

A short ordering checklist

  1. Function: dissipative surface, grounding path, or both at different points of the assembly?
  2. Resistance quantity and target range.
  3. Test method, voltage, conditioning and reading time.
  4. Contact face and mating surface.
  5. Installed compression and allowed relaxation.
  6. Cleaning agents and handling cycles.
  7. Part form: sheet, roll, slit strip, die-cut, laminated, adhesive-backed.
  8. Documentation: what the receiving inspection will actually check.

Where to go next

The two material pages set out the grade data in full: IXPE anti-static foam and IXPE conductive foam. For selection by application, see ESD foam, conductive foam tray and semiconductor packaging foam. If you want a recommendation against a drawing, send the drawing and the ESD requirement through the selection request.